Plug in flowmeter troubleshooting

2020-04-05 19:28:18
second

The instrument panel can be used to check the medium level of various kinds of tower, tank, tank, spherical vessel and heating furnace. The liquid level meter of this series of products can ensure high sealing, leak proof and applicable to high temperature, high pressure and corrosion resistant places. It fills in the defects of poor quality and easy to crack of glass (tube) liquid level indicator, and there is no blind spot in process measurement, clear display information and large measurement scope. The raw materials of the parts and components of the magnetic flap liquid level gauge are 1Cr18Ni9Ti, 316L, OCr18Ni9Ti, 1Cr18Ni9Ti lined with PTFE (polytetrafluoroethylene), PVC, PP and other raw materials and imported components, which are reliable and corrosion-resistant.

There shall be no magnetic field near the main body of the action, otherwise it will immediately endanger the working of the liquid level gauge. In the whole process of transportation so as not to damage the floating ball parts, the floating ball parts shall be removed from the main pipe of the liquid level meter before the original factory. After the installation of the liquid level meter, open the sewage treatment flange at the bottom end, and then install the floating ball parts into the main pipe of the behavior again. Pay attention to that the heavy end of the floating ball parts is upward, and can not be inverted. The side mounting method or by-pass valve tube side mounting method shall be used when the bar flowmeter is required to measure liquid. The main body of magnetic column turning is refitted with column turning liquid level indicator, liquid level power switch and liquid level intelligent transmitter. The magnetic module is placed inside the floating ball or connected with the floating ball according to the small chain. When the floating ball and the magnetic module change with the liquid level, the magnetic pattern (magnetic flap hook) is rotated; the magnetic liquid level power switch is in the position matching the liquid level point; in addition, the liquid level controller, under the effect of the floating ball's magnetism, outputs the standard data signal of the change resistor, and then the intelligent transmitter turns the data signal of the resistor It is converted into 4 ~ 50mA current data signal output. Selection of measurement method and common fault clearing characteristics of gas bar flowmeter

2. The tested medium and mark structure shall be completely protected, with good sealing property, leakage prevention, liquid level measurement under high pressure, high temperature and etching standards, and high credibility. It is widely used and installed in various forms, suitable for the measurement of liquid level and page of all media.

3. It integrates on-the-spot marking, remote transmission, automatic alarm opening, and can be adjusted at will. It has perfect functions with night light, consecutive visualization, conspicuity, large measurement scope, and the viewing direction can be changed at will.

4. It has good vibration resistance, and can be integrated into the work under the condition of large liquid level fluctuation with simple structure, convenient installation and low maintenance cost.

5. With delicate tile corrector, adjust the performance parameters at will on the spot.

Common problems in the application of magnetic flap liquid level meter

1. For the liquid level gauge exceeding a certain length (general type > 3M, anti-corrosion type > 2m).

2. The installation position of the magnetic flap liquid level gauge shall bypass or eliminate the import and export trade office of raw materials and media, so as to prevent the rapid transformation of some areas of raw materials and hydrodynamics, and endanger the measurement of liquid level

3. When the instrument panel of remote transmission supporting facilities is installed, the following shall be ensured:

4. The instrument panel of remote transmission supporting facilities shall be close to the core pipe of liquid level gauge and fixed with stainless steel plate hoop (iron system is prohibited);

5. The magnetic induction surface on the instrument panel of remote transmission supporting facilities shall face and be close to the core pipe;

6. When adjusting, first open the gate valve of the leading pipe at the upper end, then slowly open the gate valve at the lower end to allow the medium to enter the core pipe stably (during operation, prevent the medium from rushing against the floating ball, causing the floating ball to fluctuate dramatically, indicating the hazard information), check whether the rotation of the magnetic white red ball is normal, then close the gate valve of the leading pipe, open the filter valve, so as to reduce the liquid level in the core pipe If the operation is normal for three times, the fund can be put into operation (except for corrosion and other unique liquid);

7. According to the medium condition, the core tube of the magnetic flap liquid level gauge shall be cleaned regularly to eliminate the residue;

流量计厂家排除故障


Label

Recent:

Related products

Related news

situation
product
service
database
support
contact

Tel:029-89669970

24-hour hotline:186 8186 1537

Production address:Block a, building 14, innovation and entrepreneurship Park, Lintong District, Xi'an City, Shaanxi Province

Office address:9 / F, building 1, Beihang Science Park, Chang'an District, Xi'an City, Shaanxi Province