Application of bar flowmeter

2020-04-04 17:55:24
second

The bar type steam flowmeter is suitable for the operation of high precision flow meters of steam body, liquid and steam. Weiba is a kind of differential pressure type and velocity average type air flow meter. The verapamil reflects the true water flow of the fluid, with a precision of ± 1.0% and repeatability of ± 0.1%. The outstanding advantages of Vespa are as follows: output a very stable and non pulsating gas pressure data signal of beverage 1. Main use of bar type steam flowmeter

2. Probe design features

The probe with the cross section of bullet head can cause the pressure distribution of * * * and the fixed fluid separation point; the low-pressure pressure pressure tapping hole located on both sides of the probe and before the fluid separation point can be converted into a stable gas pressure data signal, and it can prevent blocking reasonably. The internal integrated structure can prevent water leakage of data signal, improve the compressive strength of probe structure, and maintain long-term high precision.

3. The flow meter uses the anti blocking design scheme, vimba total flow probe, with its anti blocking design scheme, completely solves the problem that Annubar and other plug-in total flow probes are easy to block, so that the anti blocking level of the total flow probe of the constant speed tube achieves the height width ratio of.

In general, the low-pressure hole of Vespa is substantially blocked. Under the action of vortex street force, dust, gravel and particles are concentrated at the back of the probe. That's why autumn leaves have been concentrated behind downwind houses. Other probes are located in the vacuum pump area at the end of the probe because of the low-pressure tap hole. Under the action of vortex street force, the low-pressure tap hole of the probe is quickly blocked by the residue generated by the vortex. Vespa's unique design allows the low pressure taphole to be located on both sides of the probe, at the front of the fluid separation point and the wake area. In essence, this kind of design scheme can avoid blocking and create a very stable low-voltage data signal. The high pressure tap hole of the probe is not easy to be blocked in the front side of the probe to generate a high pressure area, and the working pressure is slightly higher than the negative pressure of the pipeline, which prevents the particles from entering. It must be noted that the flow rate at the high pressure tap hole of the probe is zero, and there is no matter supplied by the flowmeter that will enter the tap hole. When starting, under the negative pressure effect of the pipeline, the fluid enters the elbow and quickly produces the situation of balanced working pressure. When the working pressure balance state is generated, the fluid encounters high pressure at the elbow inlet, bypasses and does not enter the elbow.

● it can measure a wide variety of substances, and the application scope is universal. 4. Advantages of probe

High precision and large measurement range ratio

● probe pressure hole is substantially blocked

● the measured data signal is stable with small fluctuation

● low pressure loss of pipeline

Special bullet shaped double cavity structure with high toughness

● low installation cost, maintenance free foundation

● be able to install and maintain online

巴类流量计用途

Label

Next:Overview of bar flowmeter2020-04-04 18:03:10

Recent:

Related products

Related news

situation
product
service
database
support
contact

Tel:029-89669970

24-hour hotline:186 8186 1537

Production address:Block a, building 14, innovation and entrepreneurship Park, Lintong District, Xi'an City, Shaanxi Province

Office address:9 / F, building 1, Beihang Science Park, Chang'an District, Xi'an City, Shaanxi Province